Table 5. Summary of Duplicate Measurements

Measurement TALK µmol/kg pH Total runs
Duplicates 0.3 ± 2.3 -0.001 ± 0.008 62
Replicates
System A 0.1 ± 1.2 0.001 ± 0.004 59
System B 0.1 ± 1.0 0.000 ± 0.003 74
Spectrophotometer   0.0004 ± 0.0025 1051
Combined -0.1 ± 1.1 0.001 ± 0.003 133
Spectrophotometer - Titrator   0.015 ± 0.013 1414