3e. Computation of Apparent Oxygen Utilization (AOU):
The Apparent Oxygen Utilization (AOU) value was obtained by subtracting the measured value from the saturation value computed at the potential temperature of water and 1 atm total pressure using the following expression based on the data of Murray and Riley (1969):
| - 22.2040(TK/100) + Sal [-0.037362 + 0.016504(TK/100) |
| - 0.0020564(TK/100)2], |
where TK is temperature in °K and Sal in the Practical Salinity (PS) scale.