C C Jun 23 2004 @0934 C C Miscl Metadata wrt data file chem-allp-1970-2001-24d-4-pices-wg1-04a.txt C C Column Column Contents C # Label Data type and units... C 1 GYRD Decimal Year computed from UTC Date+Time C 2 LATY Decimal Latitude [-90.0,+90.0] C 3 LNGY Decimal Lngitude [-180.0,+180.0] (-/W, +/E) C 4 CRUIS Cruise ID C 5 STN Station ID ("-" if value is missing) C 6 PRS Sea Water Pressure (dbar) C 7 SWT Sea Water Temperature (C) C 8 SALBTL Salinity from Bottle Samples [(ppt,pss78) depending on vintage] C 9 SALCTD Salinity from CTD (pss78) C 10 OXYGEN Dissolved Oxygen (umol/kg) C 11 PO4 Phosphate (umol/kg) C 12 NO3+NO2 Nitrate plus Nitrite (umol/kg) C 13 SIO4 Silicate (umol/kg) C 14 NH4 Ammonia (umol/kg) C 15 CHLA Chlorophyll-a (ug/L) C 16 TALK Total Alkalinity (umol/kg) C 17 1 TALK Method C "T" = analysis by Titration (Keith Johnson says "Open Cell method used since March 1999") C Millero closed cell used from cruise 9403 to March 1999 - problems with method C 18 2 TALK DQ Flag (see OSAP DQ flag descriptions appendix I) C 19 DIC Dissolved Inorganic Carbon (umol/kg) C 20 1 DIC Method C "C" = analysis by Coulometer (1990's, ...) C "I" = analysis by Vacuum Extraction and Infra-Red Analysis C [see Wong, C.S., Deep-Sea Research, 1970, Vol 17, pp 9-17] C "G" = analysis by Gas Chromatograph (1980's) C "T" = analysis by Titration (1970's) C I would recommend that you use ONLY DIC data from method "C" C since precision and accuracy on earlier methods was poor. J.Page C 21 2 DIC DQ Flag (see OSAP DQ flag descriptions appendix I) C 22 P_PROD Primary Productivity (hourly) (mg C.m^-3.hr^-1) C C C Data quality is expressed with the following flags: C ----------------------------------------------------------------------------- C a = Sample for this measurement was drawn from water bottle but not analyzed C (not normally used). C b = Acceptable measurement (Flag 'b' also reported as ' ') C c = Questionable measurement (no problem observed in sampling or analysis, C but value is not trusted, nonetheless; includes outlyers). C d = Bad measurement (known problem with sampling or analysis, but not C serious enough to completely discard the value). C e = Not reported (lost sample; unredeemably bad measurement). C f = Mean of replicate measurements. C g = Manual chromatographic peak measurement. C h = Irregular digital chromatographic peak integration. C i = Sample not drawn for this measurement from this bottle (not normally C used). C ----------------------------------------------------------------------------- C C All the data should go through some rigorous process of adding data quality flags. C This has not been done prior to 1999 (except 1993, 1994 WOCE cruises) C C