Underway measurements metadata form
- Investigator:
- Name: Ludger Mintrop
- Organization: Marianda
- Address:
Tulpenweg 28
24145 Kiel
Germany
- Phone: +49 431 719497-39
- Email: info@marianda.com
Investigator #2:- Name: Arne Körtzinger
- Organization: IFM/GEOMAR
- Address:
Düsternbrooker Weg 20
24105 Kiel
Germany
- Phone: +49 431 600 4205
- Email: akoertzinger@ifm-geomar.de
- Dataset Info:
- Dataset ID:
- Submission Dates:
- Initial Submission: 2006/05/31
- Revised Submission:
- Cruise Info:
- Experiment:
- Experiment Name: Cruise no. 36
- Cruise:
- Cruise ID: 06MT36_2
- Section: 2
- Geographical Coverage:
- Geographical Region:
North Atlantic - Bounds:
- Westernmost Longitude: -22.021
Degrees, Minutes, Seconds: E - Easternmost Longitude: -1.108
Degrees, Minutes, Seconds: E - Northernmost Latitude: 59.503
Degrees, Minutes, Seconds: N - Southernmost Latitude: 28.902
Degrees, Minutes, Seconds: N
- Temporal Coverage:
- Start Date: 1996/06/22
- End Date: 1996/07/17
- Ports of Call:
- Vessel:
- Vessel Name: Meteor
- Vessel ID:
- Country: Germany
- Vessel Owner: Federal Republic of Germany/Reedereigemeinschaft Forschungsschiffahrt
- Variables Info:
- Variable:
- Variable Name: Temperature, water
- Description of Variable: deg C
- Method Description:
- Equilibrator Design:
- Equilibrator type: bubbler/thin-film combination
- Equilibrator volume:1
- Water_Flow_Rate: 2
- Headspace_Gas_Flow_Rate:0.8
- Vented: Yes
- Measurement Method: infrared measurement on wet gas - reference: Kiel underway pCO2 system (Körtzinger et al., Mar. Chem. 52 (1996) 133-145). Calibration frequency: every 5 h; measurement frequency for air measurements: every 90 min; measurement frequency for water measurements: every 1 min; before reporting are measurements averaged with 10 points per minute average
- Manufacturer of Calibration Gas: Scott Specialty Gases Inc. (0 ppmv, 349.52 ppmv, 450.70ppmv)
- C02 Sensors:
- Manufacturer: unknown - unspecified infrared sensor
- Model:
- Environmental Control:
- Resolution: ± 0.5 µatm; ± 2 µatm (water); ± 0.5 ppm; ± 1 ppmv (air)
- Uncertainty:
- Calibration:
- Other sensors:
- Manufacturer: unknown
- Model: unspecified thermosalinograph
- Resolution: precision: 0.02 °C; accuracy: 0.1 °C
- Calibration:
- Method References:
- Additional Information:
What corrections were made to the CO2 concentration data prior to reporting it:
1) xCO2 corrected for pressure and temperature fluctuations during measurements
2) xCO2 corrected for dilution and pressure broadening due to water vapor
3) values averaged over 1 minute
4) xCO2 converted to fCO2 using measured atmospheric pressure and water vapor pressure at equil. temp
5) fCO2 at equil. temp. converted to in-situ temp.(fCO2 is=fCO2 eq* exp(0.0423* T))
Depth of sea water intake (in m): approx. 5.8 m below sea level ("moon pool")
location of air intake: near the "monkeys island"(20 m above sea level) - Data Set References:
- Citation:
Underway fCO2 measurements in the North Atlantic Ocean from cruise 06MT36_2 (M36/2)
- Data Set Link: