Index of /ftp/oceans/CARINA/H.Mosby/58AA9918
Please cite this data set as:
Omar, A., A.Olsen. 2007. H. Mosby 58AA19991003 cruise data from the 1999 cruises,
CARINA Data Set. http://cdiac.ornl.gov/ftp/oceans/CARINA/H.Mosby/58AA9918/.
Carbon Dioxide Information Analysis Center, Oak Ridge National Laboratory, US Department
of Energy, Oak Ridge, Tennessee. doi: 10.3334/CDIAC/otg.CARINA_58AA19991003
# Data from I. Skjelvan 7/5/05
# Ship: Haakon Mosby
# Cruise: 58AA9918
# Dates: 10/03 - 10/11/1999
# EXPOCODE: 58AA19991003
# Region: South of Svalbard
# Chief Scientists: Abdirahman Omar and Are Olsen
# 115 stations with 1-12 place Rosette
# Hydro: Who - Sonke Maus; Status - not correted
# Notes: Temperature and Salinity are the values from the CTD.
# There are some samples with high salinity and low temperature due to brine release.
# Density calculated with CTD Salinity
# Bottle salt QC'ed against CTD salt
# Cast number set to 1 for all samples
# In original file column labeled "depth" was really pressure (assumed and depth calcualted)
# Nuts: Who - Inst of Marine Research, Bergen; Status - final
# Note: units converted to umol/kg using CTD salinity and assumed lab temperature of 25C
# No oxygen data
# Anomalous points noted and forwarded to Abdir
# Flags checked and updated by Abdir Omar (12/13/05)
# Nutrient samples were frozen
# Some of the nitrate and phosphate values look strange against pressure, but nothing really stands out as anomalous when plotted against each other.
# Measurement precision appears to be too poor to do much primary QC
# O2: Who - ; Status - No data in file.
# TCO2: Who - Abdirahman Omar and Are Olsen; Status - final
# Notes: data for stations 1, 2, and 3 are questionable.
# Anomalous points noted, but no flags changed
# Coulometric titration with SOMMA system
# Estimated precision 5.6umol/kg
# CRM batch 42; CRM runs 5.9 to 49 umol/kg LOWER (mean/std 16.9+/-10.5) than certified value. Average standard deviation of CRM replicates 1.14umol/kg
# Values adjusted to CRM assuming linear drift between CRM runs and correction applied multiplicatively
# TA: Who - Abdirahman Omar and Are Olsen; Status - final
# Notes: data for stations 1, 2, and 3 are questionable.
# Anomalous points noted, but no flags changed
# Open cell titration
# CRM used, batch 42; CRM analysis gave results that were between 92 umol/kg lower than to 41 umol/kg higher than certified value.
# Standard deviation of CRM duplicates was 2umol/kg.
# Samples adjusted to CRM by multiplication assuming liner drift between CRM runs.
# Estimated precision 5.9umol/kg
# fCO2: Who - Abdirahman Omar; Status - Not ready yet.