Index of /ftp/oceans/CARINA/H.Mosby/58AA9918

[ICO]NameLast modifiedSizeDescription

[DIR]Parent Directory  -  
[TXT]58AA19991003.exc.csv16-Dec-2008 10:49 80K 

Please cite this data set as:

Omar, A., A.Olsen. 2007. H. Mosby 58AA19991003 cruise data from the 1999 cruises, 
CARINA Data Set. http://cdiac.ornl.gov/ftp/oceans/CARINA/H.Mosby/58AA9918/. 
Carbon Dioxide Information Analysis Center, Oak Ridge National Laboratory, US Department 
of Energy, Oak Ridge, Tennessee. doi: 10.3334/CDIAC/otg.CARINA_58AA19991003  

# Data from I. Skjelvan 7/5/05 
# Ship: Haakon Mosby 
# Cruise: 58AA9918 
# Dates: 10/03 - 10/11/1999 
# EXPOCODE: 58AA19991003 
# Region: South of Svalbard 
# Chief Scientists: Abdirahman Omar and Are Olsen  
# 115 stations with 1-12 place Rosette 
# Hydro: Who - Sonke Maus; Status - not correted 
# 	Notes: Temperature and Salinity are the values from the CTD. 
# 	There are some samples with high salinity and low temperature due to brine release. 
# 	Density calculated with CTD Salinity 
# 	Bottle salt QC'ed against CTD salt 
# 	Cast number set to 1 for all samples 
# 	In original file column labeled "depth" was really pressure (assumed and depth calcualted) 
# Nuts: Who - Inst of Marine Research, Bergen; Status - final 
# 	Note: units converted to umol/kg using CTD salinity and assumed lab temperature of 25C 
# 	No oxygen data 
# 	Anomalous points noted and forwarded to Abdir 
# 	Flags checked and updated by Abdir Omar (12/13/05) 
# 	Nutrient samples were frozen 
# 	Some of the nitrate and phosphate values look strange against pressure, but nothing really stands out as anomalous when plotted against each other.  
# 	Measurement precision appears to be too poor to do much primary QC 
# O2: Who - ; Status - No data in file. 
# TCO2: Who - Abdirahman Omar and Are Olsen; Status - final 
# 	Notes: data for stations 1, 2, and 3 are questionable. 
# 	Anomalous points noted, but no flags changed 
# 	Coulometric titration with SOMMA system 
# 	Estimated precision 5.6umol/kg 
# 	CRM batch 42; CRM runs 5.9 to 49 umol/kg LOWER (mean/std 16.9+/-10.5) than certified value. Average standard deviation of CRM replicates 1.14umol/kg 
# 	Values adjusted to CRM assuming linear drift between CRM runs and correction applied multiplicatively 
# TA: Who - Abdirahman Omar and Are Olsen; Status - final 
# 	Notes: data for stations 1, 2, and 3 are questionable. 
# 	Anomalous points noted, but no flags changed 
# 	Open cell titration 
# 	CRM used, batch 42; CRM analysis gave results that were between 92 umol/kg lower than to 41 umol/kg higher than certified value. 
# 	Standard deviation of CRM duplicates was 2umol/kg.  
# 	Samples adjusted to CRM by multiplication assuming liner drift between CRM runs. 
# 	Estimated precision 5.9umol/kg 
# fCO2: Who - Abdirahman Omar; Status - Not ready yet.